{"product_id":"thermo-sheild-copy-copy-copy","title":"Thermo-Shield® Roof Coat","description":"\u003ch2 data-start=\"206\" data-end=\"233\"\u003eThermo-Shield® Roof Coat\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0820\/4976\/1562\/files\/SAFETY_DATA_SHEET_Thermo-Shield_Roof_Coat.pdf?v=1772049751\"\u003e\u003cstrong\u003eSafety Data Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-start=\"235\" data-end=\"553\"\u003eThermo-Shield® Roof Coat is a high-performance, \u003cstrong data-start=\"283\" data-end=\"334\"\u003eenergy-saving, water-based acrylic roof coating\u003c\/strong\u003e engineered with \u003cstrong data-start=\"351\" data-end=\"392\"\u003evacuum ceramic microsphere technology\u003c\/strong\u003e. These microscopic ceramic spheres form sealed air cells that create a seamless, flexible membrane and a highly efficient thermal barrier over the roof surface.\u003c\/p\u003e\n\u003cp data-start=\"555\" data-end=\"971\"\u003eThis \u003cstrong data-start=\"560\" data-end=\"582\"\u003enon-toxic, low-VOC\u003c\/strong\u003e coating bridges hairline cracks, resists harsh chemicals and dirt pickup, and delivers \u003cstrong data-start=\"670\" data-end=\"697\"\u003eexcellent UV protection\u003c\/strong\u003e. With high reflectance and emittance and very low thermal conductivity, Thermo-Shield® Roof Coat significantly reduces heat penetration, thermal shock, and noise transmission—keeping roof surfaces cooler in hot weather while maintaining flexibility in extreme temperatures.\u003c\/p\u003e\n\u003chr data-start=\"973\" data-end=\"976\"\u003e\n\u003ch2 data-start=\"978\" data-end=\"993\"\u003eTypical Uses\u003c\/h2\u003e\n\u003cp data-start=\"995\" data-end=\"1180\"\u003eRoof coating systems where seams, joints, cracks, and penetrations are reinforced with polyester fabric, or anywhere a \u003cstrong data-start=\"1114\" data-end=\"1167\"\u003edurable, weather-resistant, membrane-like coating\u003c\/strong\u003e is required.\u003c\/p\u003e\n\u003chr data-start=\"1182\" data-end=\"1185\"\u003e\n\u003ch2 data-start=\"1187\" data-end=\"1205\"\u003eKey Performance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1209\" data-end=\"1225\"\u003eReflectance:\u003c\/strong\u003e 89%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1234\" data-end=\"1248\"\u003eEmittance:\u003c\/strong\u003e 94%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1257\" data-end=\"1282\"\u003eThermal Conductivity:\u003c\/strong\u003e 0.05 W\/m·K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1298\" data-end=\"1306\"\u003eVOC:\u003c\/strong\u003e 39.5 g\/L (0.33 lbs\/gal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1335\" data-end=\"1359\"\u003eService Temperature:\u003c\/strong\u003e –40°C to 204°C (–40°F to 400°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1396\" data-end=\"1412\"\u003eFlexibility:\u003c\/strong\u003e Remains flexible to –45.6°C (–50°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1453\" data-end=\"1482\"\u003eWater Ponding Resistance:\u003c\/strong\u003e Excellent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1497\" data-end=\"1510\"\u003eWarranty:\u003c\/strong\u003e See system requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1538\" data-end=\"1541\"\u003e\n\u003ch2 data-start=\"1543\" data-end=\"1569\"\u003eSubstrate Compatibility\u003c\/h2\u003e\n\u003cp data-start=\"1571\" data-end=\"1689\"\u003eExcellent adhesion to wood, urethane foam, galvanized steel, aluminum, asphalt shingles, concrete, asbestos, and more.\u003c\/p\u003e\n\u003chr data-start=\"1691\" data-end=\"1694\"\u003e\n\u003ch2 data-start=\"1696\" data-end=\"1718\"\u003eMoisture Management\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1722\" data-end=\"1748\"\u003eVariable Permeability:\u003c\/strong\u003e Breathable when dry, watertight when wet\u003c\/li\u003e\n\u003cli\u003eAllows trapped moisture vapour to escape while preventing water intrusion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1870\" data-end=\"1873\"\u003e\n\u003ch2 data-start=\"1875\" data-end=\"1905\"\u003eFilm Thickness Requirements\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1909\" data-end=\"1924\"\u003eFlat Roofs:\u003c\/strong\u003e 700 microns DFT (27 mils)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1955\" data-end=\"1982\"\u003eSloped \/ Pitched Roofs:\u003c\/strong\u003e 300 microns DFT (12 mils)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2010\" data-end=\"2013\"\u003e\n\u003ch2 data-start=\"2015\" data-end=\"2024\"\u003eColors\u003c\/h2\u003e\n\u003cp data-start=\"2026\" data-end=\"2111\"\u003eWhite and custom colours available\u003cbr data-start=\"2059\" data-end=\"2062\"\u003e\u003cem data-start=\"2062\" data-end=\"2111\"\u003eNote: Darker colours provide lower reflectivity.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr data-start=\"2113\" data-end=\"2116\"\u003e\n\u003ch2 data-start=\"2118\" data-end=\"2127\"\u003ePrimer\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePrimer is generally not required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"2167\" data-end=\"2185\"\u003eBitumen roofs:\u003c\/strong\u003e Acrylic Flex Tac bonding coat required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"2229\" data-end=\"2248\"\u003eRusty surfaces:\u003c\/strong\u003e Rust treatment required before application\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Sketch Nanotechnologies","offers":[{"title":"Default Title","offer_id":51749773443354,"sku":"TS Roof Coat1","price":1250.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0820\/4976\/1562\/files\/Roof-Coat-Thermoshield-brand2.jpg?v=1772819215","url":"https:\/\/wearingwilliams.com\/products\/thermo-sheild-copy-copy-copy","provider":"Wearing Williams","version":"1.0","type":"link"}